Home›Study Resources›Physics›
What is the National Grid?
Physics
GCSE

What is the National Grid?

The National Grid is a system of cables and transformers linking power stations to consumers. Step-up transformers increase the potential difference for the transmission cables. Step-down transformers then decrease it to a much lower value for domestic use. High potential difference means a lower current, so less energy is lost as heat in the cables. Example: 100 kW is sent at 20 000 V. I = P ÷ V = 100 000 ÷ 20 000 = 5.0 A Answer: current = 5.0 A

Quick answer: The National Grid uses step-up transformers to raise the potential difference, which lowers the current and the energy wasted as heat in the cables, then step-down transformers for homes.

What the specification expects

The National Grid is covered in 4.2.4.3 The National Grid of the AQA GCSE Physics specification (8463). You need to know:

  • the National Grid is a system of cables and transformers linking power stations to consumers
  • electrical power is transferred from power stations to consumers using the National Grid
  • step-up transformers are used to increase the potential difference from the power station to the transmission cables, then step-down transformers decrease it, to a much lower value, for domestic use
  • explain why the National Grid system is an efficient way to transfer energy
  • power = potential difference × current, P = VI, and power = current² × resistance, P = I²R: students should recall and apply both equations
  • the construction and operation of transformers is Higher tier and physics only

Method

  1. State what the step-up transformer does to the potential difference.
  2. Use P = VI to show the current falls when the potential difference rises.
  3. Use P = I²R to show the heating loss in the cables falls.
  4. Link the smaller loss to an efficient transfer of energy.

Worked example 1: finding current

A power station sends 100 kW (100 000 W) through cables at 2000 V. Calculate the current.

  1. P = VI, so I = P ÷ V.
  2. I = 100 000 ÷ 2000.

Answer: I = 50 A

Worked example 2: energy lost as heat

The cables have a resistance of 2.0 Ω. Calculate the power wasted as heat when the current is 50 A.

  1. P = I²R.
  2. P = 50² × 2.0.
  3. P = 2500 × 2.0.

Answer: P = 5000 W

Worked example 3: after stepping up

The potential difference is stepped up to 20 000 V for the same 100 kW. Calculate the new current and the power wasted in the same cables.

  1. I = P ÷ V = 100 000 ÷ 20 000 = 5.0 A.
  2. P = I²R = 5.0² × 2.0 = 25 × 2.0 = 50 W.

Answer: I = 5.0 A and the power wasted = 50 W

Worked example 4: comparing

Compare the power wasted in examples 2 and 3 and explain what this shows.

  1. The potential difference is ten times larger, so the current is ten times smaller.
  2. The wasted power falls from 5000 W to 50 W, which is 100 times smaller.
  3. Less energy is lost as heat, so the transfer is more efficient.

Answer: The loss falls by a factor of 100, so high potential difference makes the National Grid an efficient way to transfer energy.

Common mistakes

  • Saying step-up transformers increase the current. They increase the potential difference and the current falls.
  • Mixing up step-up and step-down transformers.
  • Saying a transformer makes energy. Power out cannot exceed power in.

FAQs

Are the numbers in the worked examples real National Grid values?

No. They are simplified numbers chosen to show the pattern. The specification does not give grid values for you to learn.

Do I need the transformer turns equation?

The equation linking potential differences to the number of turns is Higher tier and physics only. The specification says it is given on the Physics equation sheet.

Want one-to-one help? Find an online Physics tutor with ExpertTutor.

Reviewed by

Want one-to-one support?

One-to-one online tuition can help you build confidence in your subject. Find a tutor who teaches your course.

Find a Tutor

Learn face to face in Glasgow

Prefer in-person lessons? Visit the ExpertTutor Glasgow Southside centre.

See the centre